71x28x71 mm | TC-900R power |
| For cooling and defrosting, works with two sensors, one being for ambient temperature and the other fixed to the evaporator that controls defrost ending. With the powerful 16-Amp relay, directly controls compressors up to 1HP. The defrost output has a 10A current capacity, as well as also having Normally Closed (NC) contact available. It also has indicators in °C and °F and digital filters, which have the purpose of simulating an increase in mass in the environment sensor (S1), thus increasing its response time (thermal inertia) and preventing unnecessary activations of the compressor. Application example: walk-in and display freezers. »
Product manual
| |
 |
71x28x71 mm | TC-910R |
| It features four control outputs, two for cooling (dual-stage), one for defrosting, and one for evaporator’s fans. Its defrosting output relay has dual-throw contact (NO and NC) that can be used to switch off the condenser’s fan during defrost. It also includes two independent hour meters for signaling maintenance intervals of compressors.
Additionally, it allows presetting a pre-defrost time, adjustable for the collection of gas before starting the defrost phase. Application example: plug-in. »
Product manual
| |
 |
71x28x71 mm | TC-920R |
| It controls evaporator´s fans, besides managing defrost cycles. It can work up to three sensors, two for temperature measurement and other fixed to the evaporator that controls defrost ending and fan return.It features one digital input that can receive external pulses to synchronize defrost starting or simply to signal the status of chamber door. Its third sensor measures the ambient temperature in the air return and selects the active setpoint based on the temperature difference between return and supply sensors (S3-S1). Application example: walk-in and display freezers. »
Product manual
| |
 |
71x28x71 mm | TC-900R |
| For cooling and defrosting. It works with two sensors, one for ambient temperature and other fixed to the evaporator that controls defrost ending. Application example: walk-in and display freezers. »
Product manual
| |
 |
| |
 |
71x28x71 mm | TC-940R |
| Digital temperature controller which has four outputs: for defrost, fan, compressor and alarm. It starts the defrost cycles only when necessary, based on the evaporator temperature. Using it you can obtain a greater performance and lower power consumption. Application example: walk-in and display freezers. »
Product manual
| |
 |
90x44x44 mm | TC-900RG2 Slim |
| Dedicated digital instrument for beverage displays by a single module. It has two sensors (environment sensor and other to manage the defrost) and three outputs: compressor, ventilation (fans) and for defrost by electric resistance. Featuring a 16Amp powerful relay, it commands up to 1HP compressors at 250Vac without the need of a magnetic contactor. Application example: beverage displays. »
Product manual
| |
 |
91x45x20 mm | TC-900RG2P |
| Digital temperature controller with two sensors and outputs for compressor, fan and defrost heating element. Application example: beverage display cases. »
Product manual
| |
 |
90x44x44 mm | MT-439 plus |
| Fully configurable and dedicated refrigeration controller. It has four settings options (preset recipes) selectable through an extern switch. Each preset recipes can have its values changed individually to better customize the customer needs. By using an internal True-RMS voltage monitor and three relay outputs it is possible to safely command the compressor, light and auxiliary output, allowing to set the latter as fan or optionally as defrost system. It also features two digital inputs for open door signaling and economic operation mode selection. It has a serial communication for connection to Sitrad.
| |
 |
71x28x71 mm | MT-512R |
| Digital instrument for walk-in and display coolers with natural defrost function by compressor shutdown and permanent ventilation. It features a 16Amp powerful relay that commands up to 1HP compressors without the need of a magnetic contactor, associated a timer with a programmable cooling and defrosting times. It also has a programmable Digital Filter which prevents the compressor from constant switches while the door is temporarily open. This filter aims to simulate an increase in the environmental mass through sensor 1 (S1) thus increasing the thermal reaction time (thermal inertia). Application example: walk-in, cooling chambers and display coolers. »
Product manual
| |
 |
Ø 60x40mm prof. | MT-512C |
| Controller with a natural defrost function through compressor stop and permanent ventilation. It has an output, which is internally commanded by a temperature controller attached with a timer, and programmable defrost cycles.
With a 16A. Application example: cold and refrigerated counters. »
Product manual
| |
 |
| |
 |
71x28x71 mm | MT-512R LOG |
| Digital instrument for walk-in and display coolers with natural defrost function by compressor shutdown and permanent ventilation. It features a 16Amp powerful relay that commands up to 1HP compressors without the need of a magnetic contactor, associated a timer with a programmable cooling and defrosting times. It also has a programmable Digital Filter which prevents the compressor from constant switches while the door is temporarily open. This filter aims to simulate an increase in the environmental mass through sensor 1 (S1) thus increasing the thermal reaction time (thermal inertia).
Besides, an internal datalloger to storage data, which enables to record the average temperature and the controller output status at user-defined time intervals. Therefore it allows to collect the data continuously without the need of a computer permanently connected, once all the data can be later sent via RS-485 serial communication. It has a serial communication for connection to Sitrad. Application example: supermarkets, grocery stores, perishable shipments and cold storage chambers. »
Product manual
| |
 |
71x28x71 mm | AutoPID  |
| For cooling and heating processes, uses PID control (Proportional – Integral – Derivative), which allows controlling the temperature with high degree of stability. It has an analog output from 0 to 10 Vdc and PWM output. It has a serial communication for connection to Sitrad. Application example: cold storage chambers, stoves, laboratories, and injection machines. »
Product manual
| |
 |
71x28x71 mm | TIC-17RGT |
| Easy to set up and easy to install instruments. They can be applied to control either heating or cooling. They feature a single key to allow adjusting all their parameters.
Available in 16A for direct operation of circulation pumps up to 1HP.
It operates in the range from -50 to 200°C. »
Product manual
| |
 |
Ø 60x40mm prof. | TIC-17C |
| Easy to set up and easy to install instruments. They can be applied to control either heating or cooling. They feature a single key to allow adjusting all their parameters.
Available in 16A for direct operation of circulation pumps up to 1HP.
It operates in the range from -50 to 200°C. »
Product manual
| |
 |
76x60x38 mm | TIC-17S |
| Easy to set up and easy to install instruments. They can be applied to control either heating or cooling. They feature a single key to allow adjusting all their parameters.
Available in 16A for direct operation of circulation pumps up to 1HP.
It operates in the range from -50 to 200°C. »
Product manual
| |
 |
90x44x44 mm | TIC-17G |
| Easy to set up and easy to install instrument. It´s applied for control of both heating and cooling systems which has a single key to adjust all of its parameters. The difference lies in its dimensions that offers better visualization at a distance. »
Product manual
| |
 |
71x28x71 mm | TIC-18Ri |
| The TIC-18Ri features an internal battery with an approximate operating time of 50 hours without power, an alarm buzzer and a dialer output that can be used to indicate power fault, temperature out-of-range, or sensor not working.
It allows configuring two setpoints (primary and secondary) and recording the maximum and minimum temperatures registered. It has a single key to adjust all the functions and to manually deactivate the outputs. It can be powered either by 115/230 Vac or 12/24 Vac/dc, and features a 16-amp relay to drive motors of up to 1 HP or 4000W resistances. Application example: boilers, furnaces, heaters and freezers. »
Product manual
| |
 |
71x28x71 mm | MT-511R |
| Thermostats featured to allow serving many cooling and heating applications.
Available in 16A for direct operation of circulation pumps up to 1HP. »
Product manual
| |
 |
Ø 60x40mm prof. | MT-511C |
| Thermostats featured to allow serving many cooling and heating applications.
Available in 16A for direct operation of circulation pumps up to 1HP. »
Product manual
| |
 |
71x28x60 mm | MT-511RJ |
| Temperature controller and indicator that records maximum and minimum temperatures ranging from 100 to 600C°, with type J* thermocouple sensor.
* Sensor not included. »
Product manual
| |
 |
71x28x71 mm | MT-518Ri |
| With dual-stage, its outputs can be applied either for cooling or heating. Their secondary outputs can also be set for out of range alarms. Application example: air conditioning systems. »
Product manual
| |
 |
Ø 60x40mm prof. | MT-518C |
| With dual-stage, its outputs can be applied either for cooling or heating. Their secondary outputs can also be set for out of range alarms. Application example: air conditioning systems. »
Product manual
| |
 |
Ø 60x40mm prof. | MT-516CVT |
| It has with integrated cyclic timer and digital input. It is distinguished by its True RMS monitoring feature (from 180 to 300 Vac) that prevents the compressor from damage due to voltage fluctuations. It features programmable adjustment for minimum and maximum operating voltages. Application example: milk cooling tanks. »
Product manual
| |
 |
71x28x71 mm | MT-516RVT plus |
| It has with integrated cyclic timer and digital input. It is distinguished by its True RMS monitoring feature (from 180 to 300 Vac) that prevents the compressor from damage due to voltage fluctuations. It features programmable adjustment for minimum and maximum operating voltages. It has a serial communication for connection to Sitrad. Application example: milk cooling tanks. »
Product manual
| |
 |
71x28x71 mm | MT-516R |
| For controlling and indicating temperature, they can be configured for cooling or heating.
They feature an integrated cyclic timer. Application example: heat pumps and milk coolers. »
Product manual
| |
 |
Ø 60x40mm prof. | MT-516C |
| For controlling and indicating temperature, they can be configured for cooling or heating.
They feature an integrated cyclic timer. Application example: heat pumps and milk coolers. »
Product manual
| |
 |
| |
 |
| |
 |
135x75x34 mm | PENTA III |
| Portable thermometer that indicates the temperature at five different points. Due to its wide versatility, it is excellent for measuring temperature in central, automotive, and wall-mounted air conditioning equipment; freezers; for frigorific balancing of evaporators, among others. It has unique features such as recording minimum and maximum temperatures, HOLD function (locking of instantaneous, minimum and maximum indications), display of average and differential temperatures, besides the configurable automatic power off. »
Product manual
| |
 |
| |
 |
71x28x71 mm | TI-07R |
| Thermometers featuring decimal display and OFFSET adjustment key. They are excellent for application in frigorific equipment, machine tools, stoves, furnaces, automotive, air-conditioned rooms, and food, chemical and drug industries. »
Product manual
| |
 |
Ø 60x40mm prof. | TI-06 |
| Thermometers featuring decimal display and OFFSET adjustment key. They are excellent for application in frigorific equipment, machine tools, stoves, furnaces, automotive, air-conditioned rooms, and food, chemical and drug industries. »
Product manual
| |
 |
76x60x38 mm | TI-02 |
| Thermometers featuring decimal display and OFFSET adjustment key. They are excellent for application in frigorific equipment, machine tools, stoves, furnaces, automotive, air-conditioned rooms, and food, chemical and drug industries. »
Product manual
| |
 |
91x45x20 mm | BIGTHERM |
| It large dimensios and design allows to watch the temperature at some distance. It has an OFFSET adjustment key, which allows displacing the temperature indication. »
Product manual
| |
 |
*
True RMS: Is the real and effective voltage value which also includes the voltage generated by high frequency noise in the distributing network (harmonic distortion). This is the actual voltage applied to the connected load (example: electric motor, compressor). This method allows the precise voltage measurement for any type of wave form. Other measurement methods give correct value of applied voltage only for perfect sine wave forms. | |